44 SIEIDrive • Lift Control System
Dati in Ingresso
input Data • Caractéristiques d’Entrée • Eingangsdaten • Datos de Entrada
Sizes - AGL50 2040 2055 2075
Uln • ac Input voltage Vac three-phase network 380 V (-15%) ... 480 V (+10%)
Lift Drive • AGL50
Introduction
Fln • Input frequency Hz 50 Hz – 2 % ... 60 Hz + 2 %
Overvoltage threshold Vdc 800 Vdc
Undervoltage threshold
@ 380-400 Vac Vdc 380 Vdc
@ 420-440 Vac Vdc 405 Vdc
@ 460-480 Vac Vdc 415 Vdc
In • AC Input current for continuous service
Connection with 3-phase reactor @ 400 Vac A 9 13 16
Connection with 3-phase reactor @ 480 Vac A 8.2 11.7 14.3
Connection without 3-phase reactor @ 400 Vac A 9 13 16
Connection without 3-phase reactor @ 480 Vac A 10 15 20
THD of input current % > 100 % (without choke)
Max short circuit power without line reactor kVA 500 650 850
(Zmin=1%)
Braking IGBT Unit Standard internal (requires external resistor); Braking torque 150%.
No-load consumption (Energy rating): W 11.6 11.6 11.6
Stand-by consumption "Fan Off"