          1.7	 Output	Data


                                                      Pn mot                                                        ADV200 - 4
                      Inverter Output
                                     (Recommended asynchronous  motor rating, fsw = default)  Maximum   Output
                                                                                output
             Sizes                                                            voltage U2  frequency f2 IGBT braking
            ADV200    Heavy   Light       Heavy Duty          Light Duty                                unit
                      Duty    Duty       (150% overload)     (110% overload)

                      [kVA]   [kVA]   @400 Vac  @460 Vac  @400 Vac  @460 Vac      [V]        [Hz]                   ADV200-DC
                                        [kW]      [Hp]      [kW]      [Hp]
           1007        1.7     3.0      0.75       1         1.5        2
           1015        3.0     4.0      1.5        2         2.2        3
           1022        4.0     5.3      2.2        3         3          5

           1030        5.3     6.6      3.0        5         4          5                                           ADV200 - 6
           1040        6.6      9       4.0        5         5.5       7,5                             Internal
                                                                                                     (with external
           2055         9      11.4     5.5        7.5       7.5       10                              resistor);
                                                                                                     braking torque
           2075        11.4    15.9     7.5        10        11        15                             150 % MAX
           2110        15.9    21.5      11        15        15        20                                           ADV100
                                                                                            MAX:
           3150        21.5    26.3      15        20       18.5       25                 FVCL=300 Hz
                                                                                          FVOL=150 Hz
           3185        26.3    32       18.5       25        22        30                  VF=500 Hz
           3220         32     43        22        30        30        40
                                                                                             min:
           4300         43     52        30        40        37        50                  FVCL=0 Hz                ADV80
                                                                                          FVOL=0.5 Hz  Internal
           4370         52     60        37        50        45        60                  VF=1 Hz     optional
                                                                                             (*)
           4450         60     73        45        60        55        75                            (with external
                                                                                                       resistor)
                                                                                0.98 x Uln
           5550         73     104       55        75        75        100
                                                                                (Uln = AC                           AFE200
           5750        104     125       75       100        90        125
                                                                               input voltage)
           5900        125     145       90       125        110       150
           61100       145     173      110       150        132       175
           61320       173     208      132       175        160       200

           71600       208     267      160       200        200       250                                          FFE200
           72000       267     319      200       250        250       300
           72500       319     409      250       300        315       400
                                                                                                     External optional
           73150       409     450      315       400        355       450
                                                                                            MAX:      (BUy series)
           73550       450     506      355       450        400       500                FVCL=200 Hz               SMB200
                                                                                          FVOL=150 Hz
           400 kW      506     603      400       500        500       650                 VF=200 Hz

           500 kW      603     776      500       650        630       850
                                                                                             min:
           630 kW      776     852      630       850        710       950                 FVCL=0 Hz
                                                                                          FVOL=0.5 Hz
           710 kW      852     956      710       950        800      1100                 VF=1 Hz                  PROGRAM.
                                                                                             (*)
           900 kW      1108    1247     900       1200      1000      1300

           1 MW        1247    1420     1000      1300      1200      1600

                                                                                                                    APPENDIX
          (*) For Brushless motors:
          MAX: FVCL/ FVOL =280 Hz, min: 10% of rated frequency
          FVCL = Flux vector CL (Field Oriented Control with feedback); FVOL=Flux vector OL (Open Loop Field Oriented Control).