Page 19 - Gefran - Inverter system and power supply unit (ADV200 Drive family)
P. 19
Gefran S.p.A. - Drive & Motion Control Unit • www.gefran.com 19
1.7 Output Data
Pn mot ADV200 - 4
Inverter Output
(Recommended asynchronous motor rating, fsw = default) Maximum Output
output
Sizes voltage U2 frequency f2 IGBT braking
ADV200 Heavy Light Heavy Duty Light Duty unit
Duty Duty (150% overload) (110% overload)
[kVA] [kVA] @400 Vac @460 Vac @400 Vac @460 Vac [V] [Hz] ADV200-DC
[kW] [Hp] [kW] [Hp]
1007 1.7 3.0 0.75 1 1.5 2
1015 3.0 4.0 1.5 2 2.2 3
1022 4.0 5.3 2.2 3 3 5
1030 5.3 6.6 3.0 5 4 5 ADV200 - 6
1040 6.6 9 4.0 5 5.5 7,5 Internal
(with external
2055 9 11.4 5.5 7.5 7.5 10 resistor);
braking torque
2075 11.4 15.9 7.5 10 11 15 150 % MAX
2110 15.9 21.5 11 15 15 20 ADV100
MAX:
3150 21.5 26.3 15 20 18.5 25 FVCL=300 Hz
FVOL=150 Hz
3185 26.3 32 18.5 25 22 30 VF=500 Hz
3220 32 43 22 30 30 40
min:
4300 43 52 30 40 37 50 FVCL=0 Hz ADV80
FVOL=0.5 Hz Internal
4370 52 60 37 50 45 60 VF=1 Hz optional
(*)
4450 60 73 45 60 55 75 (with external
resistor)
0.98 x Uln
5550 73 104 55 75 75 100
(Uln = AC AFE200
5750 104 125 75 100 90 125
input voltage)
5900 125 145 90 125 110 150
61100 145 173 110 150 132 175
61320 173 208 132 175 160 200
71600 208 267 160 200 200 250 FFE200
72000 267 319 200 250 250 300
72500 319 409 250 300 315 400
External optional
73150 409 450 315 400 355 450
MAX: (BUy series)
73550 450 506 355 450 400 500 FVCL=200 Hz SMB200
FVOL=150 Hz
400 kW 506 603 400 500 500 650 VF=200 Hz
500 kW 603 776 500 650 630 850
min:
630 kW 776 852 630 850 710 950 FVCL=0 Hz
FVOL=0.5 Hz
710 kW 852 956 710 950 800 1100 VF=1 Hz PROGRAM.
(*)
900 kW 1108 1247 900 1200 1000 1300
1 MW 1247 1420 1000 1300 1200 1600
APPENDIX
(*) For Brushless motors:
MAX: FVCL/ FVOL =280 Hz, min: 10% of rated frequency
FVCL = Flux vector CL (Field Oriented Control with feedback); FVOL=Flux vector OL (Open Loop Field Oriented Control).