Page 75 - Gefran - Inverter system and power supply unit (ADV200 Drive family)
P. 75

Gefran Spa - Drive & Motion Control Unit • www.gefran.com               75





          4.8	 Cooling

          All inverters are fitted with internal fans (+ 24V) and threshold control (ON @ 55°C and OFF @ 45°C).     ADV200 - 4

                                                 Pv (*)                           Fan capacity
                       Size                 (Heat dissipation)         Heat sink                Internal
                                                                                                   3
                                                                           3
                                                  [W]                    [m /h]                  [m /h]
                   1040                           120                      32                      -
                   1055                           160                     2 x 56                   -                ADV200-DC
                   2075                           200                     2 x 56                   -
                   2110                           250                     2 x 32                   -
                                                                                                                    ADV200 - 6
                   3150                           300                     2 x 80                   32
                   3185                           380                     2 x 80                   32
                   3220                           460                     2 x 80                   32
                   4300                           600                    2 x 250                  2 x 50
                   4370                           900                    2 x 250                  2 x 50
                                                                                                                    ADV100
                   4450                           1000                   2 x 250                  2 x 50
                   5550                           1290                   2 x 285                 1 x 170
                   5750                           1760                   2 x 355                 2 x 170
                   5900                           2150                   2 x 355                 2 x 170

                                                                                                                    ADV80
          (*) : @Uln=400..460Vac, values that refer to operation at default switching frequency.