Tests and Testing Procedures per IEC/EN Standards (continued)                                            14
                                                                                                                    597
           Material Tests

          All WAGO products meet requirements for the following material tests:

          • Needle Flame Test to IEC/EN 60947-1
          This test simulates flames that may arise under certain conditions (e.g, fault current over a creepage distance, overloading parts
          or components). Nearby parts can also be affected by such flames. Not only is the ignition of the test specimen resulting from an
          intrinsic defect tested, but also its behavior when other parts are ignited.




                                                               Flames shall not be further fed by the insulation materials used,
                                 Terminal block                creating a larger fire. The test specimen is exposed to a stan-
                                                               dard gas flame during a defined time period (e.g.,10 seconds).
                                                               After the test flame has been removed, the specimen must self-
                                                     Mount     extinguish within 30 seconds. Furthermore, a layer of tissue
               Terminal block
                                                               paper located beneath the specimen shall not be ignited by
                                                               glowing particles falling from the specimen.

                           Mount
           Lateral insulation wall  Tissue paper  Clamping part in
                                              the area
                                              of the clamping unit
                          Pinewood board  Point of test
                   Test arrangement    flame contact














          • Glow-Wire Test to IEC/EN 60998-1, IEC/EN 60695-2-11
          In the event of failure, a high current may cause a conductor to glow.


                                             However, the glowing conductor shall not  The test is to be passed if there are no
                                             cause ignition of the product involved   visible flames or permanent glowing, or if
                                             (e.g., a rail-mounted terminal block). For   flames or glowing extinguish within 30
                                             the glow-wire test, the tip of the glow-wire  seconds after removal of the glow-wire.
                                             is pressed against a surface of the test   Furthermore, a layer of tissue paper loca-
                                             specimen (see picture).            ted beneath the specimen shall not be
                                             The position of the test specimen, surface  ignited by glowing particles falling from
                                             to be tested, test duration, and glow-wire  the specimen.
                                             temperature (e.g., 960°C over 30
                                             seconds, or 850°C over 5 seconds) are
                                             specified in the standards.