Page 77 - Parker - Fluoropolymer hose and fittings products
P. 77
Hose Assembly & Crimping
Field Attachable - 90 Series
4 5 6
Assembly Assembly Assembly
By hand, push sleeve over end Verify tube butts against inside Using SAE 20 weight oil, lubri-
of PTFE core tube and under shoulder of ferrule. cate nipple and socket threads.
wire braid. For stainless steel fittings use
Parker ThreadMate™ or a
molybdenum type lubricant.
Warning
Do not use lubricating oil when
installing fittings on hose used in
oxygen service. When installing
fittings on hose used in oxygen
service lubricate with a non-oil
based soap solution. Failure to
do so may result in an explosion
and personal injury when hose
To complete positioning of Using a tapered punch, push is used.
sleeve, push hose end with punch into end of sleeve and
sleeve against a solid flat tube to set sleeve barbs into
surface. tube.
Technical Assemble hose – Using a
twisting motion, push hose
over nipple until hose is seated
against nipple chamfer.