Page 14 - TRD
P. 14

  Provision of Anti monkey climbing devises:
                 The reason for around 21% CB Trippings in the divison are due to electricution of

                 monkeys. The monkey menance are lofty in DKJ, Aler and NKD sections in the
                 Division. To decress the monkey menance, division has taking many streps and
                 anti  monkey  climbing  devices  are  one  among  those.  1126  Anti  monkey
                 climbing devices are provided.












                                       Fig: AMCD provided at DKJ junction.

                Muff raising:

                    Muff  is  an  additional  concreting  done  on  top  of  foundation  to  prevent
                 accumulation of water around the mast and thus prevents corrosion of mast at
                 the  foundation  level.  Due  to  aging  and  other  factors  the  Muff  in  many
                 locations  are  destroyed.  Muffing  was  provided  for  486  locations  in  ALER
                 section.












                                               Fig: Muffing work@ Aler
                Replacement of Rusted ACC:
                 In polluted areas like SNF and KI, TDU, the anti-creep wires became rusted, due
                 to  this  the  mechanical  strength  of  the  wire  was  decreased.  The  snapping  of

                 which may leads to major breakdown. To avert this Division has come up with
                 replacement  of  rusted  Anti  Creep  wires.  Total  33  rusted  Anti  creep  wires  are
                 replaced.
   9   10   11   12   13   14   15   16   17   18   19