Page 88 - GM booklet 2019 test
P. 88

7. Provision of Safety bracket for CHT cable in 3- Phase EMU Motor coaches.

            Safety Bracket has been provided to CHT cable which is carrying 25 KV power supply at under
            frame of 3- Phase EMU Motor coaches to avoid damage to CHT cable in case of Cattle run over
            or external hitting.














                                             Safety bracket provided to CHT cable


              8. Provision of Clamping arrangement to BP & MR Hose End Angle cocks for
                  Ferrule type SS Pipe line fittings




              There are 02 Failures online due to MR & BP Hose pipe along with angle cock end fitting
              came out from ferrule. Therefore an additional clamping arrangement is provided to BP & MR
              Hose end Angle cocks for ferrule type SS Pipe line fittings to avoid failures online.














                              No clamping on angle end cock      clamping provided on angle end cock


            9.  Fitment of Pneumatic horns on roof top of Motor coaches  :


            02 Nos of pneumatic horns are fitted on roof top in all the EMU & MEMU motor coaches in view
            of  complaints  received  from  Loco  pilots  that  the  Horn  sound  was  coming  inside  the  cab  and
            causing disturbance to the Loco pilots. (Existing horns retained for use in emergency).
















                       Fitment of 02 Nos of new Pneumatic horns on roof top of EMU Motor coach.



                                                            78
   83   84   85   86   87   88   89   90   91   92   93