Viewing Measurement Data
Trigger Icon Trigger
Stator Current Correlation
High-Tuned Temperature Dependence
Low-Tuned Temperature Dependence
Resonance
Looseness
Multiple Triggers
- No Trigger
Note:
Measurements that are collected using a single-shot measurement
(refer to Section 9.1.11) will always have a '-' symbol in the Trigger
column.
Measurements collected from original GuardII and EVTracII monitors
will always have a '-' symbol in the Trigger column.
• The ‘Phase Quality’ column shows an icon indicating how consistent the phase
summary numbers will be. This column can be filtered.
Phase Quality
Icon Meaning
This measurement was collected with a shaft trigger signal.
The Phase summary numbers will be suitable for trending.
This measurement was collected without a shaft trigger signal.
The Phase summary numbers will not be suitable for trending.
This measurement was collected asynchronously.
The Phase summary numbers will not be suitable for trending.
The measurement is not suitable for ODS analysis.
Note:
Measurements collected from original GuardII and EVTracII monitors
will always have an ‘asynchronous’ symbol in the Phase Quality
column.
• The ‘Status’ column shows the top-level measurement status. Note that there is a
hierarchy to the status; ‘error’ has a higher priority than ‘clipped’ and ‘clipped’ has a