Page 110 - Condition Monitor User Manual
P. 110

Viewing Measurement Data




                                   Trigger Icon    Trigger
                                                   Stator Current Correlation

                                                   High-Tuned Temperature Dependence

                                                   Low-Tuned Temperature Dependence


                                                   Resonance

                                                   Looseness

                                                   Multiple Triggers

                                         -         No Trigger



                                       Note:
                                       Measurements that are collected using a single-shot measurement
                                       (refer to Section 9.1.11) will always have a '-' symbol in the Trigger
                                       column.
                                       Measurements collected from original GuardII and EVTracII monitors
                                       will always have a '-' symbol in the Trigger column.

                          •  The  ‘Phase  Quality’  column  shows  an  icon  indicating  how  consistent  the  phase
                              summary numbers will be.  This column can be filtered.


                            Phase Quality
                                 Icon       Meaning
                                            This measurement was collected with a shaft trigger signal.
                                            The Phase summary numbers will be suitable for trending.
                                            This measurement was collected without a shaft trigger signal.
                                            The Phase summary numbers will not be suitable for trending.
                                            This measurement was collected asynchronously.
                                            The Phase summary numbers will not be suitable for trending.
                                            The measurement is not suitable for ODS analysis.


                                       Note:
                                       Measurements collected from original GuardII and EVTracII monitors
                                       will  always  have  an  ‘asynchronous’  symbol  in  the  Phase  Quality
                                       column.
                          •  The ‘Status’ column shows the top-level measurement status.  Note that there is a
                              hierarchy to the status; ‘error’ has a higher priority than ‘clipped’ and ‘clipped’ has a