Viewing Measurement Data



                              higher priority than ‘ok’.  This means that if some inputs from a single measurement
                              are reporting ‘error’ and some are reporting ‘clipped’, then the overall status is ‘error’.

                             Status Icon    Meaning

                                            The measurement status is ‘ok’.

                                            One or more inputs shows a ‘clipped’ status.  This means that the
                                                raw EV signal is too large to read correctly.
                                            One or more inputs is reporting a hardware error.

                          •  The ‘Line Current’ column indicates the Line Current Operating Condition at the time
                              of  the  measurement.    If  Line  Current  was  not  available  at  the  time  of  the
                              measurement, this will be blank.  The measurement list can be sorted by this column.
                          •  The ‘Temperature’ column indicates the asset Temperature Operating Condition at
                              the time of the measurement.  If Temperature was not available at the time of the
                              measurement, this will be blank.  The measurement list can be sorted by this column.

                          •  The ‘Active Power’ column indicates the Active Power Operating Condition at the
                              time  of  the  measurement.    If  Active  Power  was  not  available  at  the  time  of  the
                              measurement, this will be blank.  The measurement list can be sorted by this column.
                          •  The ‘Reactive Power’ column indicates the Reactive Power Operating Condition at
                              the time of the measurement.  If Reactive Power was not available at the time of the
                              measurement, this will be blank.  The measurement list can be sorted by this column.

                          •  The ‘Operating Point’ column indicates whether the detected operating point at for
                              this measurement was ‘FLH’, ‘FLC’, ‘RLH’, ‘Synchronized’ (the Shaft Trigger was the
                              correct speed, but the Operating Conditions were not correct for the other Operating
                              Points)  or  ‘Unknown’  (the  Shaft  Trigger  was  not  at  the  correct  speed,  and  the
                              Operating  Conditions  were  not  correct  for  the  other  Operating  Points).    The
                              measurement list can be sorted and filtered by this column.


                                       Note:
                                       Measurements collected from original GuardII and EVTracII monitors
                                       will always have an ‘Unknown’ Operating Point.

                          •  The ‘Comment’ column shows a User-editable comment about the measurement.

                          •  The remaining columns show the Summary Number selected by the ‘Measurement
                              Parameter to Display’ selection described above.  There is one column for each axis
                              in the database.  The measurement list can be sorted by each of these columns.
                          Columns in the measurement list can be hidden, resized and/or rearranged as desired.
                          To select which columns to show:

                          •  Right-click on the heading of any column in the list.