Page 66 - Condition Monitor User Manual
P. 66
Configuring a Monitor
Figure 7-7 GuardII+ Endwinding Vibration Settings
For each input, select the signal that is connected to that input. As each input is
connected, the status information and the diagram are updated. Status is shown using an
icon shown next to the input and the text in the input information box located below the input
list.
Note:
Any EV signal can be connected to any EV input, with two exceptions:
• Signals that are linked, must be connected to the same physical
connector. This means that linked signals can be connected to
(for example) EV1 and EV2, or EV15 and EV16. Linked signals
cannot be connected to EV1 and EV3, or to EV6 and EV7. This
is handled automatically by the software; when one half of a
linked signal is assigned, the other half is automatically
assigned as well.
• Do not put a signal on the second input of a connector until the
first input is used. This means that you cannot assign a signal
to (for example) EV18 until EV17 has been used; similarly, do
not assign a signal to EV28 until EV27 has been used.
60
www.irispower.com