                                            Figure 6-8 IAM Phase Naming Schema
              6.2.3.  Sensor Setup

                        Once the asset is created in the database, EV sensors need to be added to the asset.
                     Select the asset in IAM, and then Add EV Sensors.
























                                                 Figure 6-9 Add EV Sensors
                        Adding EV sensors is a multi-step process:

                        •  The first page of the EV sensor setup shows a list of the sensors that exist on the
                            machine.  Note that these represent the physical sensors themselves.  A sensor is
                            defined by its serial number, type and the number of axes that it can monitor.  Also, if
                            the machine has a Shaft Trigger installed, select the checkbox.