Page 68 - GuardII+ Series 4208 Platform EV User Manual
P. 68
Troubleshooting
7.2.3. EV Terminations
If there is a problem with the data, there may be a problem with one or more EODs; check
the operation of the EODs as described in the EOD Box Manual and Installation Guide.
7.2.4. Alternate Monitor
If a second GuardII+ is available, this can be used for validating that the sensors are
working properly. Run a measurement using the alternate device and compare the results to
the GuardII+.
• If the results are similar, then both devices are likely working properly.
• If the results are significantly different, then there is likely a problem with one of the
devices.
7.3. Iris Power LP Contact Information
Email: Technical Support – techsupport.iris@qualitrolcorp.com
General Inquiries – info@irispower.com
Sales – sales.iris@qualitrolcorp.com
Field Service – fs.admin@irispower.com
Field Service Scheduling – scheduling@irispower.com
Phone: +1-905-677-4824
Between 09:00 and 17:00 (GMT-5hrs)
Fax: +1-905-677-8498
Address: Iris Power LP
3110 American Drive
Mississauga, ON L4V1T2
Canada
If technical support is required, please provide the following information (the more
information about the issue, the faster the resolution):
• Contact data (name, e-mail address, telephone number)
• GuardII+ Series 4208 Platform serial number
• Hardware and Software versions
• Symptoms
• The IID database used in IAM
• The diagnostics downloaded from the GuardII+
• On-site troubleshooting results
Other company and product details are available at www.irispower.com.