Page 74 - MNU-PM502- Pharmaeutical Microbiology Theoritical Book
P. 74

Pharm D- Clinical Pharmacy Program        Third Level          Pharmaceutical Microbiology& Antimicrobials (PM 502)



                 Class 4 :        Two or more critical          Pouches
            Multi-Variable        variables.
                                  Change color only when
                                  exposed to a given
                                  temperature for a
                                  specified time

                 Class 5 :        react to all the critical     Integrators
               Integrating        variables of the specific
               (Integrators)      sterilization process
                                  in steam cycles (time,
                                  temperature, and
                                  moisture)

                 Class 6 :        All critical variables for    Cycle Verification
              Emulating           specified sterilization       They should only be used in the
               indicator          cycles                        specific cycle for which they are
                (Cycle                                          labeled
             Verification)




                      3-  Biological indicators
                •  Standardized bacterial spore preparations which are usually in the form either of
                        ➢  suspensions in water or culture medium
                        ➢  spores dried on paper, aluminum or plastic carriers

                  Self-contained biological indicator

                  Spore strip and nutrient medium are present in the same device ready for mixing

                  after use