Page 39 - type de document
P. 39
EOS 90396-A-PHY-0003-Columns assembly
i. Depending on your situation. If you have limited space clearance or any restrictions throughout
the transport path, you can adjust the CTT and transport the column at an angle. This technique
reduces the footprint but increases the height.
j. If clearance is not your problem, transport the column in horizontal position close enough to the
floor to lower the center of gravity
Figure 7 - Column securely attached to CTT and ready to be erected
k. Once the column is in the room, is time to
position it on top of the Nivell.
l. Bring the column as close as possible to
the Nivell of the chosen plane. Make sure
the column is aligned in the proper
direction
m. Make sure the Nivell surface is clean and
apply a slight touch of lubricant on top of
the four quadrants.
n. You will need to carefully rotate, lift and
reposition the column accordingly with
respect to the Nivell until the column is
fully erected and directly on top of the
Nivell but not fully resting on it yet.
Figure 8 - Column Driven into position