EOS          90396-A-PHY-0003-Columns assembly




                                IMPORTANT: Tighten and torque one column first following TABLE 1 but DO
                                NOT tighten the second one yet.
                                You need to complete the “Centering Position Bars” procedure to the
                                column that has not been bolted down yet.


                                                       TABLE 1


                                                                       STEP 1


                                                 Check level using inclinometers and adjust levelling bolts if
                                                 necessary - Requires 17mm key

                                             1
                                                 Follow this cross-tightening sequence described below
                                                 Required criteria = < 0.02 mm

                                                 You will need two separate torque wrenches for this


                                                               STEP 2 - TORQUE 50Nm

                                             2   Tighten bolt position 2 to 50 Nm and check column level


                                             3   Tighten bolt position 3 to 50 Nm and check column level

                                             4   Tighten bolt position 4 to 50 Nm and check column level


                                             5   Tighten bolt position 5 to 50 Nm and check column level

                                                              STEP 3 - TORQUE 100 Nm


                                             6   Tighten bolt position 6 to 100 Nm and check column level

                                             7   Tighten bolt position 7 to 100 Nm and check column level


                                             8   Tighten bolt position 8 to 100 Nm and check column level


                                             9   Tighten bolt position 9 to 100 Nm and check column level

                                                              STEP 4 - TORQUE 150 Nm

                                             10   Tighten bolt position 10 to 150 Nm and check column level


                                             11   Tighten bolt position 11 to 150 Nm and check column level

                                             12   Tighten bolt position 12 to 150 Nm and check column level


                                             13   Tighten bolt position 13 to 150 Nm and check column level