Page 111 - CRS Engineering
P. 111
Proforma for Joint Inspection on R. A. T.
For the Year 2020 -21
SI Description Remarks
No
I General Particulars of RAT
1 Name of the tank Maddiledu Tank
2 District Chittoor District
3 Name of the Village and Mandal Maddiledu Village, Srikalahasti Mandal
4 Latitude & Longitude Lat 13° - 44' - 30" Long 79° - 37' - 40"
5 Affected Railway Bridge and Km The Tank Lies in-between Bridge No:-70&57 /
6 Railway section in between stations Yellakaru
7 Distance from Railway Bridge to weir 7.20 Kms from the Railway line to the tank.
( Along the Course of Nallah )
II Standard Hydraulic Details
1 Catchment Area 1.20 Sq miles
2 Capacity of the tank 25.43 MCFT
3 Lowest Bed Level -f- 97.20M
4 Full Tank Level ( F.T.L ) + 99.60M
5 Maxim Water Level ( M.W.L ) + 100.05M
6 Danger Level ( D.L ) + 100.85M
7 Top of Bund Level ( T.B.L ) + 101.05M, +101.25M
8 Top Width of the Bund 1.20M, 1.50M , 3.00M ( Present Top Width )
9 Side Slopes AT FRONT:- 1 Va : 1 , AT REAR :- 2:1
10 Area of Submergence at FTL -
11 Area of Submergence at MWL -
12 Are there any tanks in the Catchment of NO
this tank
13 Are these tanks also classified as RATs -
14 Names and details of these tanks -
Surplus Weir
III -
Number of Surplus Weirs TWO NUMBERS ONLY ( 2 Nos Only )
1
Lengths of Surplus Weir No:-1 = 14.00M, No:-2=9.50 M
2
3 Tvoe of Surplus Weir B.C WEIR
Design Discharge 207.00 Cusecs
4
IV Sluices -
Number of Sluices THREE NUMBERS ONLY ( 3 Nos Only ) —
1
Location of Sluices
2
Maximum designed discharge 2.50 CUSECS
3
Functional or not FUNCTIONAL
4
A) Inspection details
V
Sr5-02-2020
i)Date of Inspection
iONameft HP'^innaHon of the Inspection _ _ 1) Sri. C. Willson Babu,
Assistant Divisional Engineer ,
South Central Railway
RENIGUNTA
2) Sri. C.Adinarayana Naidu. B.Terh.
Deputy Executive Engineer .
Irrigation Sub Division
3) Sri. K Rajesh,B.Tech.,
Assistant Executive Engineer ,
Irrigation Section
SRIKALAHASTI