General Particulars of RAT
Name of the tank Somanagunta tank
2 District Chittoor District
3 Name of the Village and Mandal Merlapaka Village, Yerpedu Mandal
I Latitude & Longitude Lat 13° - 41' - 44" Long 79° - 36' - 19"
5 Affected Railway Bridge and Km Bridge No:-89, Location 64 / 24 - 26
6 Railway section in between stations Rachagunneri - Srikalahasti
7 Distance from Railway Bridge to weir
1 CT DsIKa/sv/ lino {"ho t"2»nL'
f\rlS rrom lMG Kaliway Illlc LU Lllc UdllK
( Along the Course of Nallah )
II Standard Hydraulic Details
1 Catchment Area 2.40 sqkm
2 Capacity of the tank 9.50 M.C.F.T
6 Lowest Bed Level +98.45 M
i. Full Tank Level ( F.T.L ) +100.00M
5 Maxim Water Level ( M.W.L ) + 100.60M
6 Danger Level ( D.L ) + 100.90M
7 Top of Bund Level ( T.B.L ) + 102.10M
8 Top Width of the Bund 3.00M ( Present Top Width )
9 Side Slopes AT FRONT:- 1 1/2 : 1 , AT REAR :- 2:1
10 Area of Submergence at FTL 1.10 Sqkm
11 Area of Submergence at MWL l.,35 Sqkm
12 Are there any tanks in the Catchment of NO
13 Are these tanks also classified as RATs -
14 Names and details of these tanks -
III Surplus Weir -
1 Number of Surplus Weirs ONE NUMBER ONLY (1 NO Only)
2 Lengths of Surplus Weir 40.00 M
3 Type of Surplus Weir B.C WEIR
4 Design Discharge 20.00 Cusecs
IV Sluices
TWO NUMBER ONLY (2 NO Only)
1 Number of Sluices
AT 5M AT610M.
2 Location of Sluices
3 Maximum designed discharge 2.50 Cusecs
Re Constructd early Year.
4 Functional or not
V A) Inspection details
<^02-2020
)Date of Inspection
i)Name& Designation ortne Inspeclmu 1) Sri. C. Wiilson Babu,
Mssistant uivibiuiiai miyuieer ,
South Central Railway
RENIGUNTA
2) Sri. C.Adinarayana Naidu, B.Tech..
Deputy Executive Engineer .
Irrigation Sub Division
3) Sri. K. Harikrishna
Assistant Engineer,
Irrigation Section
YERPEDU