Page 43 - مشروع تخرج 1
P. 43

Water inlet temperature (°C)                             Gain Output Ratio (GOR)

                 111
                 110
                                                                        8.4
                 109
                                                                        8.3
                 108
                                                                        8.2
                 107
                                                                        8.1
                 106
                                                                         8
                 105
                                                                        7.9
                 104
                                                                        7.8
                 103
                                                                        7.7
                 102
                                                                        7.6
                          1         2         3          4
                                                                        7.5
                                    Stage number
                                                                               original state   modified state

               Fig.4.3 inlet water temperature for the four-stage                                 Fig.4.3 GOR for the original plant and
               modified                                                                                           after using RSCC



                                                                      3
                                                Capacity of palnt m /day



                                        2450

                                        2400

                                        2350                                  original
                                        2300                                  modified

                                        2250

                                        2200
                                        2150

                                          Fig.4.5 capacity for the original plant and modified











                                                            -30-
   38   39   40   41   42   43   44   45   46   47   48