Eco-solution 2: Reuse of Water Condensate Presentation of Data


            Water  condensate  is  extracted  from  the  air  as  a  by-  Based on the environmental review data, we estimate
            product  in  the process of  cooling  the environment. It   a total power saving in kWh per day = 50.8 3kWh. This
            does  not  contain  chlorine  or  any  other  minerals  that   equates to estimated annual savings in kWh (based on
            may be found in drinking water. It is proposed to recycle   250 working days) = 12,707.5 kWh
            and reuse the condensate.
                                                                 Estimated total annual consumption = 71,520 – 12,707.5
            We designed and tested an electrolyser to use the water                                                                    = 58,812.5 kWh
            condensate to make a hand sanitiser for the employees.
            (See Figures 1a & b)                                 Table 8 shows the estimated carbon emission after eco-
                                                                 solution  deployment.  This  amounts  to  an  estimated
            Testing and Designing the Electrolyser               reduction of 17% of the carbon footprint.






                                                                   Resource   Annual Usage  Annual CO    Conversion
                                                                                                  2
                                                                                          Emissions      Factor
                                                                  Air –     58,812.5 kWh  24,630.7 kg CO 2  0.4188 kg CO /
                                                                                                                2
                                                                  Conditioner                             kWh


             Figure 1a:  Testing using   Figure 1b:  Designing of an   Table 8: Carbon emission after eco-solution deployment
              a DIY prototype  of an       electrolyser
                   electrolyser


                                                                 Review of Eco-Solutions by
            Excess condensate can also be used:                  SME Management

            •   To wash the shop floor;                          Our eco-solutions were presented to the management
                                                                 of CKE Manufacturing.
            •  To mix with cutting fluid for use in machinery
                   operations;                                   •   The management approved the cost savings
                                                                       associated with the modification of the air-
            •  As a dielectric fluid for use in EDM wire-cut           conditioning system. This also results in 17 %
                machines.                                              of the carbon footprint.