Page 31 - Towards A Sustainable Future , Phase 3 2025, E-Book_Neat
P. 31

A newly designed suction connector can be connected to the  ● Malfunction- Low pressure can damage or cause air source
            Smart Refrigerant Detector (SRD) to monitor the R32 multi-  equipment to malfunction.
            split air conditioning system through a single suction port. This  ● Surge- Low suction pressure can increase the likelihood of
            improved solution can enable the Smart Refrigerant Detector  surge  conditions,  which  occur  when  the  gas  flow  becomes
            (SRD) to continuously monitor the low pressure of the R32  unstable  and  can  cause  pressure  fluctuations  and  potential
            multi-split  air  conditioning  system.  Our  team  has  tested  it  damage to the compressor.
            together with the Daikin BMS engineer, and they are satisfied  ●  Overheating-  Operating  at  low  suction  pressures  can
            with this solution.                                  cause  the  compressor  to  overheat  due  to  increased  gas
                                                                 temperatures.
            Eco Solution 1                                       ● Mechanical Stress- Operating at low suction pressures can
            According  to  the  servicing  department  data,  about  20%  cause the compressor to experience higher mechanical stress,
            of  the  air  conditioning  malfunctions  are  reported  due  to  potentially leading to premature wear and tear.
            low  refrigerant  charge.  Based  on  a  study,  undercharging
            can reduce air conditioner life, capacity, and efficiency, and   5. Improve cooling capacity
            refrigerant leakage can lead to fire risk.          According to a study, lower refrigerant pressure leads to lower
            Below are some key factors to substantiate the SRD benefits:  cooling  capacity.  The  capacity  decreases  with  decreasing
                                                                refrigerant charge primarily due to a drop in refrigerant mass
            1. Reduce carbon emissions                          flow  rate.  In  general,  a  30%  reduction  in  charge  results  in
            ● Scope 1 emission - low refrigerant pressure signified pos-  about a 30% reduction in cooling capacity.
            sible refrigerant leakage; early detection can prevent further
            refrigerant leakages to the environment.            6. Prevent fire risk from the newer R32 refrigerant
            ● Scope 2 emission- low refrigerant pressure leads to higher   New R32 refrigerant is classified as A2L flammable gas. Early
            energy consumption, rectifying the leakage can reduce elec-  detection can prevent refrigerant leakages and fire incidents.
            tricity consumption.                                The user or the Air con Technician can shut off the Air con to
            ● Scope 3 emission- low refrigerant pressure reduces life   avoid further leakage into the room.
            span, early detection and rectification can increase lifespan
            and avoid the disposal of the air conditioning unit.  The performance test is conducted on the Daikin single split
                                                                unit  air  conditioner  model  RKM25PVMG.  The  purpose  is
            2. Increase air conditioning efficiency             to  determine  the  air  conditioner's  performance  during  an
            The study from Purdue University indicated that an improper   undercharged  condition.  The  test  is  done  inside  a  non-air-
            refrigerant  charge  amount  can  reduce  the  efficiency  of   conditioned  room  with  the  ambient  temperature  of  27  oC
            systems by 10 to 20% in the field.                  and humidity of 72 % RH. Based on the testing with Daikin
                                                                and the BMS Engineer, there is a significant increase in supply
            3. Reduce energy consumption                        air  temperature  when  the  air  conditioner  is  undercharged,
            According  to  a  study,  low  refrigerant  pressure  can  lead  to   as shown in Fig. 4.4. This chart shows that a low refrigerant
            higher energy consumption by 10 to 20%.             charge will reduce the cooling capacity of the air conditioner.

            4. Increase life span
            Low refrigerant pressure can reduce the life span of the air
            conditioning system. Low pressure can have an adverse effect
            on the compressor listed above.