Page 26 - QR CIMAR LASER SCREED
P. 26

STARTING THE MACHINE

Refer to the engine manual for engine starting and stopping instructions.
Warm up procedure to be used when the ambient temperature is below 32°F.

CAUTION: Hydraulic oil should be 80°F for ideal performance but should reach a minimum of 50°F
               before using machine to screed concrete. Run a hydraulic function to warm hydraulic oil,
               recommended function is propel. Do not engage pump if hydraulic oil is below -13°F.

1) Be sure that Propel Twist is off.               2) Open side door to locate fuel valve.
                                                       Be sure the fuel valve lever is ON.
                                                       NOTE: Fuel should be OFF while transporting.

3) Open side door to locate
engine stop switch. Turn
the Stop Switch clockwise
to the ON position.

4) If the engine is cold, pull the choke lever to      5) Move the throttle lever away from the SLOW
   the CLOSED position. To restart a warm                 position, about 1/3 of the way toward the
   engine, leave the choke lever down in the              FAST position.
   OPEN position.

                                                   24