Page 125 - Foton Workshop Manual - Auman EST-M
P. 125

Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts   DI - 71

              2. Check the ground circuit of urea level temperature sensor.                                       IN

              a. Ignition switch: LOCK.
              b. Disconnect the cable of battery negative pole.                                                   DI
              c. Disconnect the urea level temperature sensor connector F061 and ECM connector F099.

                                                        d.  Separately  measure  the  resistance  between  Pin  2,  4  of   EG
                                                        urea tank urea level temperature sensor connector F061 and
                                                        Pin 45 of ECM connector F099.                             TR
                                                        Standard resistance:

                                                            Multimeter connection       Standard value            AX

                                                              F061(2)-F099(45)             About 0Ω
                                                                                                                  FR
                                                              F061(4)-F099(45)             About 0Ω

              Check if the result is ok?                                                                          ST
              Yes>go to Step 3.

              NO>Repair or replace the failed harness.                                                            BR
              3. Check the signal circuit of urea level temperature sensor

              a. Ignition switch: LOCK.                                                                           BW
              b. Disconnect the cable of battery negative pole.
              c. Disconnect the urea tank urea level temperature sensor connector F061 and ECM connector F099.    EL

                                                        d. Measure the resistance between Pin 1, 3 of urea tank urea
                                                        level temperature sensor connector F061 and Pin 91, 28 of
                                                        ECM connector F099.
                                                        Standard resistance:

                                                            Multimeter connection       Standard value

                                                              F061(1)-F099(91)             About 0Ω

                                                              F061(3)-F099(28)             About 0Ω

              Check if the result is ok?

              Yes>go to Step 4.

              NO>Repair or replace the failed harness

              4. Check and replace the power harness of urea level temperature sensor

              a. Replace the urea level temperature sensor.

              b. Use the diagnosis instrument to perform DTC confirmation procedure

              c. Perform the procedure of reading the sensor data stream Confirm if the inspection result is ok








                                                          DI-071