Page 122 - Foton Workshop Manual - Auman EST-M
P. 122

DI - 68              Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts

              Check if the result is ok?
              Yes>intermittent failure
              NO>go to Step 2.

              2. Check the power circuit of nitrogen oxide sensor.
              a. Ignition switch: ON.

              b. Disconnect the nitrogen oxide sensor connector F057.

                                                        c. Measure the voltage of NOx sensor connector F057 pin 1
                                                        to ground.
                                                        Standard voltage:

                                                            Multimeter connection       Standard value


                                                              F057(1)-grounding       Battery power supply




              Check if the result is ok?
              Yes>go to Step 3.
              NO>Repair or replace the failed harness

              3. Check the ground circuit of nitrogen oxide sensor.
              a. Ignition switch: LOCK.

              b. Disconnect the cable of battery negative pole.
              c. Disconnect the nitrogen oxide sensor connector F057.

                                                        d. Measure the resistance of NOx sensor connector F057 pin
                                                        3 to ground.
                                                        Standard resistance:

                                                            Multimeter connection       Standard value

                                                              F057(4)-grounding            About 0Ω



              Check if the result is ok?
              Yes>go to Step 4.

              No>check, repair or replace the faulty ground harness.
              4. Check the signal circuit of NOx sensor CAN.

              a. Ignition switch: LOCK.
              b. Disconnect the cable of battery negative pole.










                                                          DI-068