DI - 70              Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts

              Fauty of urea tank urea level temperature sensor
              1668-Urea level sensor circuit-higher voltage over normal value or short to high-voltage power source
              1669- The voltage of urea tank urea level temperature sensor 1 circuit is lower than the normal value or
              short to the low voltage power supply

              1677- The voltage of urea tank urea level temperature sensor 1 circuit is higher than the normal value
              or short to the high voltage power supply
              1678-Urea temperature sensor circuit-voltage below normal value or short to low-voltage power source
              Overview

              1. The urea tank level temperature sensor is used to check the level and temperature of urea in the tank, and
              send the checked signal to engine ECU.
              2. The urea tank level temperature sensor shall be installed inside the urea tank.
              Circuit diagram








                                                         Engine ECM
                                                 Urea level  Sensor   Urea temperature
                                                 signal   grounding  signal






                                                     Yellow   Black   Blue   Black
                                                     - black    - white








                                                          Urea tank urea level
                                                          temperature sensor

              Diagnosis procedure
              1. Read the DTC and data on the diagnosis instrument

              a. Start the engine to run at idle.
              b. Use the diagnosis instrument to perform DTC confirmation procedure.

              c. Use the diagnosis instrument to read the sensor data stream.
              d. Adopt the diagnostic unit to read the waveform of urea tank urea level temperature sensor.
              Check if the result is ok?
              Yes>intermittent failure.

              NO>go to Step 2.