Page 132 - Foton Workshop Manual - Auman EST-M
P. 132

DI - 78              Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts

              Diagnosis procedure
              1. Check the data of engine.

              a. Ignition switch: LOCK.
              b. Connect the diagnostic unit to fault diagnostic connector (16 pin).
              c. Ignition switch: ON.

              d. Read the engine data indicated on diagnostic unit.
              Can the diagnostic unit enter into ECM module to read its data flow?
              Yes>intermittent failure.
              NO>go to Step 2.

              2. Check other module data.
              a. Read the safety airbag or ABS data indicated on diagnostic unit.

              b. Read the indicated data of diagnostic unit.
              Can the diagnostic unit enter into safety airbag or ABS module to read its data flow?
              Yes>go to Step 5.
              NO>go to Step 3.

              3. Check the communication CAN wire of ECM.
              a. Ignition switch: LOCK.

              b. Disconnect the cable of battery negative pole.
              c. Disconnect ECM connector A001.

              d. Adopt a multimeter to measure the conductivity between pin 6, 14 or B1 of diagnostic interface connector
              B013 and pin 62 or 84 of ECM connector A001.
              e. Adopt a multimeter to measure the conductivity of pin 14 or 6 of diagnostic interface connector B013 to
              ground.
              f. Turn the ignition switch to “ON” position, and adopt a multimeter to measure the resistance between pins 14
              and 6 of diagnostic interface connector B013.
              Standard resistance:

                        Multimeter connecting terminal                        Standard value

                              B013(6)-A001(62)                                   About 0Ω

                              B013(14)-A001(84)                                  About 0Ω

                              B013(6)-B013(14)                                  About 60Ω
              Standard:

                        Multimeter connecting terminal                        Standard value

                              B013(6)-A001(62)
                                                                               No breakdown
                              B013(14)-A001(84)








                                                          DI-078