Page 135 - Foton Workshop Manual - Auman EST-M
P. 135

Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts   DI - 81

              Standard:                                                                                           IN

                            Multimeter connection                             Standard value
                                                                                                                  DI
                                   85-86                                        Conduction

                                   30-87                                       No breakdown
                                                                                                                  EG
              Check if the result is ok?
              Yes>go to Step 3.                                                                                   TR
              NO>replace the fuse or relay.

              3. Check the preheating circuit.                                                                    AX

              a. Adopt a multimeter to separately measure the resistance between #30 hole seat of preheating relay R01 and
              preheating fuse GF\L3 or between #87 hole seat and preheater F019.
                                                                                                                  FR
              Standard resistance:

                            Multimeter connection                             Standard value                      ST


                               R01(30)-GF\L2
                                                                                 About 0Ω
                                                                                                                  BR
                                R01(87)-F019

              Check if the result is ok?
                                                                                                                  BW
              Yes>go to Step 4.

              No>repair the relevant harness.
                                                                                                                  EL
              4. Check the pre-heater

              a. Adopt a multimeter to measure the resistance between both ends of preheater.

              Standard resistance:

                            Multimeter connection                             Standard value

                            Two ends of pre-heater                               About 7Ω

              Check if the result is ok?
              Yes>go to Step 5.
              NO>replace the pre-heater

              5. Check the crankshaft/cam shaft position sensor and relevant circuit

              a. Check the crankshaft position sensor(Refer to “Chapter DI Diagnosis-Diagnosis of Engine Electric Control
              Fault-Fault of Crankshaft Position Sensor”)

              b.  Check  the  camshaft  position  sensor  (refer  to  Chapter  DI  diagnosis-  engine  electronic  control  fault
              diagnosis–camshaft position sensor failure)
              Check if the result is ok?

              Yes>go to Step 6.
              No>replace relevant fault sensor or faulty harness.







                                                          DI-081
   130   131   132   133   134   135   136   137   138   139   140