Page 1197 - Workshop Manual - Aumark (BJ1051)
P. 1197

53-21
                                                          Battery-Battery


               4.     Adjustment of electrolyte specific gravity
                      Full charge the battery and then measure the specific gravity when the electrolyte specific
                      gravity needs to be adjusted according to seasons changing. Suck out some electrolyte by
                      sucker if the specific gravity is not suitable; fill in distilled water if the specific gravity is
                                                                                  3
                      higher than required specific gravity; and fill in 1.40 g / cm  electrolyte if it is lower than
                      required specific gravity; charge the battery a while again and mix them evenly; check the
                      specific gravity again until it is correct. The specific gravity adjustment in winter for battery
                      should be accord with the following table.

               Discharge  Fully charged
               degree
               Specific    Specific   Freezing   Specific   Freezing   Specific   Freezing   Specific   Freezing   Specific   Freezing
                                                             gravity
                                            gravity
                                                                              gravity
                                                                                               gravity
                                                                                       point
                           gravity
                                                                      point
                                                                                                        point
                                                     point
                                    point
               gravity
               and
               freezing
               point of
               electrolyt
               e














                                                                                                                   53