Page 613 - Workshop Manual - Aumark (BJ1051)
P. 613
16-13
Cooling- Surge Tank
Replacement
1. Tilting up cab
2. Disconnecting battery negative cable
3. Opening surge tank cap
4. Disconnecting coolant level alarm
switch
(a) Disconnect connector of coolant level
alarm switch on surge tank.
16
5. Disconnecting surge tank outlet hose
(a) Loosen surge tank outlet hose hoop, and
separate the hose.
(b) Drain coolant in surge tank using special
vessel.
6. Disconnecting engine escape hose
(a) Loosen engine escape hose hoop, and
separate the hose.
7. Disconnecting radiator escape hose
(a) Loosen radiator escape hose clamp, and
separate the hose.
Page 613