Page 610 - Workshop Manual - Aumark (BJ1051)
P. 610

16-10
                                                   Cooling-Radiator





                                                           15.    Connecting radiator outlet hose
                                                           (a)    Connect radiator outlet hose, and tighten
                                                                  the fixing clamp.

                                                                  Torque: 9~11 N•m








   16








                                                           16.    Connecting radiator inlet hose

                                                           (a)    Connect radiator inlet hose, and tighten
                                                                  the fixing clamp.

                                                                  Torque: 9~11 N•m









                                                           17.    Connecting surge tank hose

                                                           (a)    Connect surge tank hose to radiator, and
                                                                  tighten the clamp.
                                                                  Torque: 9~11 N•m












          18.    Connecting related components on radiator

          (a)    Connect other related components to radiator.
          19.    Filling coolant and bleeding cooling system (refer to Service Manual for Cummins ISF
                 Series Engines)

          20.    Tilting down cab










                                                                                                         Page 610
   605   606   607   608   609   610   611   612   613   614   615