Page 34 - 26306
P. 34
36 49
7.3 Description of User Interface • To exit the DEMO mode, tap the RAYPEX 6
®
WARNINGS ® “home” icon (Fig. 37). NOTE
en For removing the charger, follow the RAYPEX 6 has a tilt adjustable front panel with a Servicing and repair work should only be en
large graphic TFT touch screen.
sequence below: carried out by service engineers trained
• Before removing the external charger The main screen shows the following icons and at the factory.
from the power outlet, disconnect the symbols:
charger from the device. The measuring cable and the surface of the
• The device cannot be used while equipment should be cleaned with a paper towel
charging. or soft cloth or wipe that has been wetted with
Settings icon aldehyde-free disinfection and cleaning solution
(bactericidal and fungicidal), e.g
• DENTIRO wipes, Oro Clean Chemie AG,
®
Switzerland
Battery Replacement Sound icon • TopActiv wipes, ad-Arztbedarf GmbH, Germany
The battery compartment is located at the rear of • SprayActiv, ad-Arztbedarf GmbH, Germany
®
RAYPEX 6 and its cover is secured by screws. Measuring cable connector and
• Release the screws and remove the battery lip clip/ file clip symbols • DY wipes, DENTSPLY, France
compartment cover.
• Remove the battery from battery compartment
and disconnect the battery cable plug from the Full canal image WARNINGS
battery jack of RAYPEX 6. Fig. 37 Exit DEMO mode • To disinfect the equipment and the
®
• Insert the cable plug of the new battery into the measuring cable, wipe the surface with
battery jack. Apical zoom image a clean cloth or wipe that has been
• Insert the battery into the battery compartment. NOTE wetted only slightly with a non-aggressive
• Close the battery compartment and secure the If the measuring cable is connected disinfectant.
cover with the screws. during the DEMO mode running, • Do not use any liquids or sprays directly
RAYPEX 6 will automatically exit the on the equipment, particularly the display.
®
DEMO mode. • Do not use strong alcohol to disinfect
WARNINGS surfaces.
• Before replacing the battery, disconnect
the charger from the device!
• The used battery must be disposed of in 8 Maintenance, cleaning and Before preparing them for reuse, remove the lip
accordance with the local regulations clip, file clip or touch probe from the measuring
sterilization cable.
The lip clip, file clip and touch probe must always
8.1 General information be cleaned, disinfected and sterilized before
they are used. This also applies before they are
used for the first time. The only way to ensure
The RAYPEX 6 is maintenance-free and does not that these accessories are effectively sterilized
®
have any components that need to be maintained is to thoroughly clean and disinfect them. When
by the user. doing this, follow the special instructions set
out in section 8.2, "Cleaning, disinfection and
sterilization".