Page 36 - scales manual v1014 web
P. 36
DORAN 8600 DISPLAY
ACTION Weigh Mode
1. Level/unload scale “ 1. CONF “
2. Close Dip Switch #9 “ 7. CAL1 “
3. Press SETP 3 times “ 7.0 C Ld “
4. Press ACCUM “ Etr CAL “
5. Press RCL “ Ent SP “
6. With platform empty, press ZERO
7. Put on test weight Set display to actual wt. “ Etr CAL “
(At least 20% of Capacity) Via digital keypad “ SAV CAL” then
8. Press ENTER “ 7.0 C Ld “
9. Press SETP “ 7. CAL1 “
“ SAVSETU “
10. Press SETP
11. Open Dip Switch #9
Calibration Complete!
EAGLE BATCH CONTROLLER Page 36
Key Assignments:
Zero- escape key
Select- Used to select digit to edit
Asterisk- Used to enter changed data
1. Press SELECT to enter setup
2. “PASS”, enter password as described below
To change number:
Press SELECT to select which digit to change
When a digit becomes editable it blinks
Press the ASTERISK to increment digit
When done editing digits, press SELECT until no digits
are blinking
To ENTER the number, press the ASTERISK
Most passwords are 00001
3. Press SELECT until “CAL” is displayed
4. Press *, “ZERO” is displayed
5. “SET”, press *
6. Get back into setup mode, “CAL”, press *
7. Press SELECT until “FULL” is displayed
8. Press *, last cal weight is displayed, press SELECT button
And change digits you desire to change
9. Press SELECT until no digits are flashing
10. Press the * button to calibrate
© 2014 ScaleResource.com
ACTION Weigh Mode
1. Level/unload scale “ 1. CONF “
2. Close Dip Switch #9 “ 7. CAL1 “
3. Press SETP 3 times “ 7.0 C Ld “
4. Press ACCUM “ Etr CAL “
5. Press RCL “ Ent SP “
6. With platform empty, press ZERO
7. Put on test weight Set display to actual wt. “ Etr CAL “
(At least 20% of Capacity) Via digital keypad “ SAV CAL” then
8. Press ENTER “ 7.0 C Ld “
9. Press SETP “ 7. CAL1 “
“ SAVSETU “
10. Press SETP
11. Open Dip Switch #9
Calibration Complete!
EAGLE BATCH CONTROLLER Page 36
Key Assignments:
Zero- escape key
Select- Used to select digit to edit
Asterisk- Used to enter changed data
1. Press SELECT to enter setup
2. “PASS”, enter password as described below
To change number:
Press SELECT to select which digit to change
When a digit becomes editable it blinks
Press the ASTERISK to increment digit
When done editing digits, press SELECT until no digits
are blinking
To ENTER the number, press the ASTERISK
Most passwords are 00001
3. Press SELECT until “CAL” is displayed
4. Press *, “ZERO” is displayed
5. “SET”, press *
6. Get back into setup mode, “CAL”, press *
7. Press SELECT until “FULL” is displayed
8. Press *, last cal weight is displayed, press SELECT button
And change digits you desire to change
9. Press SELECT until no digits are flashing
10. Press the * button to calibrate
© 2014 ScaleResource.com