Page 39 - scales manual v1014 web
P. 39
FAIRBANKS INDR 2500
1. Password is usually the last 4 of serial #
2. To reset password, press the menu key, scroll to service
menu, press the left arrow key then the right arrow key
then enter.
FAIRBANKS 5200
1. Zero scale, place cal weight on scale
2. Press Cal Switch twice
3. Press 1 and enter, then enter 3 times
4. Key in Cal weight at prompt
5. Key in Capacity at prompt
6. Press Enter through prompts
FAIRBANKS 90-164
Enter key advances To modify parameter key in new value and press enter to accept value
1. Turn on indicator
2. At dashes push the enter or zero key
3. Open instrument and push the program switch S1
4. Enter access code, 2 digits, usually last 2 digits of serial # then press enter
5. Press enter until “Zero Reference” is displayed
6. Press “ZERO” to set the zero reference
7. Load the platform with weight at the “Applied Weight Span 1”
8. Key in value and press enter
9. Press enter , display reads “ max capacity”
10. Enter 105% of capacity press enter and the indicator will exit programming mode
and display the weight on the scale.
© 2014 ScaleResource.com Page 39
1. Password is usually the last 4 of serial #
2. To reset password, press the menu key, scroll to service
menu, press the left arrow key then the right arrow key
then enter.
FAIRBANKS 5200
1. Zero scale, place cal weight on scale
2. Press Cal Switch twice
3. Press 1 and enter, then enter 3 times
4. Key in Cal weight at prompt
5. Key in Capacity at prompt
6. Press Enter through prompts
FAIRBANKS 90-164
Enter key advances To modify parameter key in new value and press enter to accept value
1. Turn on indicator
2. At dashes push the enter or zero key
3. Open instrument and push the program switch S1
4. Enter access code, 2 digits, usually last 2 digits of serial # then press enter
5. Press enter until “Zero Reference” is displayed
6. Press “ZERO” to set the zero reference
7. Load the platform with weight at the “Applied Weight Span 1”
8. Key in value and press enter
9. Press enter , display reads “ max capacity”
10. Enter 105% of capacity press enter and the indicator will exit programming mode
and display the weight on the scale.