Page 43 - scales manual v1014 web
P. 43
FLEXWEIGH SERIES 7
1. Turn off indicator and insert JP1, turn indicator on
2. “P 0” is displayed, enter 2001 and press ENTER
3. If hot key entry is enabled you can enter cal mode by pressing the GN and
ENTER keys
4. Using the PRINT and G/N keys, scroll to C6
5. Press ENTER and use the PRINT and G/N keys to scroll to C6.1
6. Press ENTER and Use PRINT key to Select RC and Press ENTER
7. C6.2 Press ENTER
8. Unload Scale and press ENTER
9. Display will show CAL and then NXXXXXX
10. Key or scroll in the cal weight value then load scale with the weight.
11. Press ENTER
12. Press ENTER to save Cal
13. Press ZERO then ENTER
FIRST WEIGH DI-12/12K
1. Slide cal switch and push button on back of indicator.
2. Push PRINT.
3. Push PRINT until ZERO 0 is displayed.
4. Push PRINT
5. Display shows a numeric value
6. Place cal weight on scale, using the lb/kg key move the cursor and increment it
with the ZERO key to display the cal weight to be used.
7. Push PRINT.
8. Slide the protection switch on the back of the indicator and press the button.
© 2014 ScaleResource.com Page 43
1. Turn off indicator and insert JP1, turn indicator on
2. “P 0” is displayed, enter 2001 and press ENTER
3. If hot key entry is enabled you can enter cal mode by pressing the GN and
ENTER keys
4. Using the PRINT and G/N keys, scroll to C6
5. Press ENTER and use the PRINT and G/N keys to scroll to C6.1
6. Press ENTER and Use PRINT key to Select RC and Press ENTER
7. C6.2 Press ENTER
8. Unload Scale and press ENTER
9. Display will show CAL and then NXXXXXX
10. Key or scroll in the cal weight value then load scale with the weight.
11. Press ENTER
12. Press ENTER to save Cal
13. Press ZERO then ENTER
FIRST WEIGH DI-12/12K
1. Slide cal switch and push button on back of indicator.
2. Push PRINT.
3. Push PRINT until ZERO 0 is displayed.
4. Push PRINT
5. Display shows a numeric value
6. Place cal weight on scale, using the lb/kg key move the cursor and increment it
with the ZERO key to display the cal weight to be used.
7. Push PRINT.
8. Slide the protection switch on the back of the indicator and press the button.
© 2014 ScaleResource.com Page 43