Page 93 - scales manual v1014 web
P. 93
WEIGHTRONIX 902

1. Press and hold PRINT key
2. Press SAMPLE to CALIB
3. Press ZERO until “Load 0”
4. Unload scale and press ZERO
5. Press SAMPLE key to scroll through weight choices
6. Load weight and press ZERO
7. “Busy, Done, Calib”, press COUNT/WEIGH

WEIGHTRONIX 1065

1. Press and hold ZERO key
2. “Pass”, Scroll in 5601 and press ENTER
3. Same as 1070

TARE =  SELECT =  ZERO = ESCAPE PRINT =  UNITS =  F1 = ENTER

WEIGHTRONIX 1070

1. Press and hold ESCAPE
2. “Pass” enter 0701 and press ENTER
3. Press PRINT, remove weight and press ENTER
4. Press ENTER to save zero data
5. Press UNITS key to display SPAN
6. Press PRINT key and enter is test weight value
7. Place weight and press ENTER
8. Press ENTER to save Span data then press ESC

WEIGHTRONIX 3265

1. Push the cal button
2. A number is displayed, enter this number in reverse order
3. 1=QC, 2=Target, 3=Units, 4=Zero
4. “Scale”, press , press , then press 
5. “CAL”, press  key, “ZERO”
6. Scale empty, press , press  key, “ZERO” is displayed
7. Press  key to move to SPAN
8. Press  key, Cal weight is displayed, press  to select alt. weight.
9. Place test weight and press  key to calibrate
10. Press  to get out

© 2014 ScaleResource.com Page 93