• Communication • Note: You must connect
to the terminal successfully
before doing the
communication setting.
1. Tick ( ) and select device
in the Device list, and click
Communication tag to enter
to the Communication
setting interface.
2. Click [Read Option] button
to read the communication
settings in the selected terminal.
3. After setting, click [Set
Option] button to save
communication settings.
IP Address, Gateway, Subnet Mask, Device ID, Password: Set as required.
• Door Option
• Note: You must connect to the
terminal successfully before
doing the Door Option setting.
1. Tick ( ) and select device in
the Device list, and click Door
Option tag to enter to the Door
Option setting interface.
2. Click [Read Option] button to
read the access parameters
setting in the selected terminal.
Lock Duration: The device controls the time to open electronic lock. (Functioning value for 1~10s)
Door Sensor Delay: After the door is opened, delay the time to check door sensor. If door sensor state is
different from the normal state of door sensor mode, alarm will be emitted. This time is called door sensor
delay. (Functioning value is 1~99.)
Door Sensor Mode: There are two options, that are normal open (NO) and normal close (NC). Normal
Open means the normal state of the door is Opened; while Normal Close means the normal state of the
door is Closed.
62 ZKTime.Net 3.0