Alarm Delay [s]: Detection to the abnormal door sensor state, the door
       sensor will generate an alarm signal after a period of time. This time is
       door sensor alarm delay. (Functioning value is 1~99s)

       NC TZ: Normal close time zone.


       NO TZ: Normal open time zone.

       Retry Time: When the failed press times reach the set times, alarm
       signal will emit. (Functioning value is 1~9 times.)

       Anti-Pass Mode: Click   button and select the anti-pass mode as
       None, Out, In, or Out/In as required.                                  3.  After setting, click [Set Option]

                                                                                button to save and modify the
       Master State: Click   button and select the master state as None,
       Control Out, or Control In as required.                                  door option.


       •  Wiegand Option
                                                                              •  Note: You must connect to
                                                                                 the terminal successfully
                                                                                 before doing the Wiegand
                                                                                 Option setting.





                                                                              1.  Tick ( ) and select device
                                                                                in the Device list, and click
                                                                                Wiegand Option tag to
                                                                                enter to the Wiegand
                                                                                Option setting interface.





                                                                              2.  Click [Read Option] button to
                                                                                read the Wiegand setting in the
                                                                                selected device.
       Wiegand Format: The system has two built-in formats, Wiegand 26-bits
       and Wiegand 34-bits.


       ID Type: Select the ID Type as ID or Pin (Emp ID) as required.

       Failed ID: Defines the output value for user authentication failures. The
       output format is determined by the setting of Wiegand format. The
       value ranges from 0 to 65535.                                          3.  After setting, click [Set Option]
                                                                                button to save and modify the
       Site Code: Similar to device ID. But the code is specified by user.      Wiegand option settings.
       Different device can be repeated. (With range of 0~255)