Page 769 - Basic Electrical Engineering
P. 769

Pitch factor,

                                            K  = cosβ / 2                 (10.4)
                                              p


                  The value of the pitch factor is somewhat less than unity. For example, if
               the coil is short pitched by an angle say 30°, then β = 30°:








               Example 10.1    Calculate the distribution factor for a single-layer 36-slot
               two-pole three-phase stator winding of a synchronous machine.



               Solution:


               Slots are made distributed throughout the whole of stator periphery. The
               angle between two slots, i.e., slot angle α is calculated as








               Number of slots per pole per phase, i.e., m is calculated as



















               Example 10.2    The stator winding of a three-phase synchronous machine
               has been wound for four-poles in 36 slots. Each coil span has an eight-slot

               pitch, i.e., the distance between the coil sides of a coil has been eight slots.
               Calculate the distribution factor and the pitch factor.



               Solution:
   764   765   766   767   768   769   770   771   772   773   774