Page 157 - Microsoft Word - 2_Inch_Drain_Adapter_PDS_2016_01_05
P. 157

DURO-GRIP  BOARD-MAX INSULATION ADHESIVE
                                                 ®
               e.  After the adhesive has attained its initial bond   6.  Re-Use of Applicator Gun After Storage:
                 strength the boards can be walked-in and will      a.  Before disengaging the trigger safety lock,
                 be compressed to the deck or substrate                remove the used nozzle.
                 exhibiting minimal slippage or movement. The
                 boards should be exposed to minimum traffic        b.  Check the face of the gun to make sure the
                                                                       outlet ports are clear and the face of the gun is
                 for at least 10 – 20 minutes (depending on
                 temperature) after they have been walked-into-        free from dirt, chemical or other debris.
                 place to avoid breaking the freshly formed         c.  If necessary, use a rag to remove any cured
                 bond.                                                 foam or chemical from the face of the gun.
               f.  Membranes can be applied once the adhesive       d. See Equipment Set Up directions on the
                 has achieved sufficient bond strength to the          previous page.
                 immediate substrate to which it is adhered. It is   7. Disposal Procedures:
                 recommended that the contractor inspect the        a.  Do not puncture or incinerate tanks.
                 installed insulation for proper adhesion and re-
                 adhere any boards and/or corners that are not      b.  After tanks are empty, they must be vented.
                 adequately attached.                                  CAUTION: Tanks will still be under pressure.
                                                                       Eye protection and impervious gloves MUST
               g.  Boards that will not lay flat due to cupping,       be worn during the procedure.
                 warping or crowning, or surface irregularities of
                 the substrate, should have weights placed on       c.  With tank valve in opposite position of use,
                 the boards until the adhesive has achieved            slowly open the tank valve, point tank AWAY
                 adequate adhesion to hold the boards in place.        from face and allow pressure to completely
                                                                       vent. CAUTION: Empty tank could contain
               h.  When spraying stops for breaks, lunch or            potential vapor toxicity hazard. Provide
                 overnight repeat the purging procedure in             adequate ventilation or respiratory protection
                 step #2h.                                             (consult SDS).
               i.  Very Important: As the hoses are exposed to      d.  DISPOSE OF EMPTY TANKS ACCORDING
                 the heat of the sun, especially in the summer         TO APPLICABLE FEDERAL, STATE AND
                 months, the pressure in the hoses will build up.      LOCAL REGULATIONS.
                 Purging the hoses for a few seconds prior to
                 spraying relieves the excess pressure and
                 allows the chemical to flow in the proper
                 proportions.
            5.  Equipment Storage and Re-Use:
               a.  Turn the tank valves off.
               b.  Store between 60 and 90° F (16 – 32° C).
               c.  The used nozzle should be left on the gun
                 during storage.
               d.  Engage the trigger safety lock.
               e.  Close the supply valves on both “A” and “B”
                 tanks.                                          Wear eye protection and impervious gloves
               f.  The dispensing gun is a disposable unit and is
                 not designed for prolonged storage or
                 continuous re-use. To help extend the storage
                 life, it is recommended to dispense a minimal
                 amount of foam from the gun at least once
                 every seven days to ensure optimum flow of
                 chemical through the hoses.
               g.  Use up the adhesive within 30 days of initial
                 use.
               h.  Make certain valves are in correct position
                 when turning them on and when operating the
                 unit.









               www.duro-last.com                           4 of 4                                 800-248-0280
                                Duro-Last, Duro-Guard, Duro-Grip and “World’s Best Roof” are registered trademarks owned by Duro-Last, Inc.
                                               Created: 03/20/2017 Revised: 03/21/2017, 03/23/2017