Page 332 - Installation Training Binder FIT1-3
P. 332
Step 6
Application
Before starting flooring application, it is recommended that the installer
read all available safety data including, but not limited to, OSHA approved
material safety data sheet, product data sheet and backup label.
Mixing
Pre-mix Part A (resin) for about 30 seconds using a jiffy mixer. Pour Part B
(hardener) into the Part A pail and mix thoroughly for 2 minutes. Pot life is
approximately 10 minutes @ 70 F in the container.
o
Jiffy Mixer
(Not included, available at any local hardware store)
Installation
o
Do not apply epoxy when surface temperature is below 35 F.
For application, the epoxy base coat/sealer resin-hardener should be at a
o
minimum temperature of 70 F.
Always pour the material as soon as it is blended. In the container,
the pot life is approximately 10 minutes. The working life once
poured is approximately 30 minutes.
Always spread immediately after pouring. Cold concrete temperatures will
cause a viscosity increase; the longer the cool surface contact before
spreading to 15 mils, the more increasingly difficult it becomes.
Add Part B to Part A and mix thoroughly. Spread the Part A and B mixture
with (3/8”) nap roller at a rate of 50 square feet per gallon (30 mils).
NOTE: Additional material will be required if surface is rough.
Allow to cure. The cure is directly related to the temperature. See the
following schedule:
o
35 F- 7 days 60 F- 48 hours
o
o
40 F- 5 days 70 F- 36 hours
o
o
o
45 F- 4 days 80 F- 24 hours
o
o
50 F- 3 days 90 F- 16 hours
EnviroGuard 800-206-9884 Fax 909-624-1772 www.enviroguard.com