Page 94 - (KU)01-75GAJ-1.5 - Change 1
P. 94
INTRO
EP'S (KU)01-75GAJ-1.5 A FIGURES
1.2.2 CAUTIONS B
ACAWS
Alert/Condition Crew Action
R POD SUP VLV NOT OPEN C GROUND
The RIGHT POD SUPPLY R POD SPLY VLV OPEN ECB (925)....
switch is set to open and the ...................................... PULL, RESET D
left pod supply valve is not R POD SPLY VLV ECB (926)................
open. ...................................... PULL, RESET E TAKEOFF
RIGHT POD supply switch........... MAN
RIGHT POD supply switch.......... Cycle F FIRE/SMK
NORM Cycle from CLSD to OPEN.
If valve fails to open: PRES/OXY
RIGHT POD supply switch......... CLSD G
Fuel transfer from RIGHT POD is
not available. H ENG/PROP
R WING A/I OVRHEAT
BA/ECS has detected an R ISO VALVE switch................ CLOSE I
overheat in the right wing FUEL
inboard or outboard ice Nacelle 3 shutoff switch........... CLOSE
protection zone(s) that was Nacelle 4 shutoff switch........... CLOSE L
not isolated. The respective AAR
ice protection zone valve may Icing conditions........................... Avoid
have failed open. Right wing ice protection zone is M
SPEC NOT FOR FLIGHT ELEC
inoperative.
If ice accumulation is suspected: N
Landing with Ice Accumulation HYD
procedure........................... Accomplish O
R WING BLD AIR LEAK ISOL
Bleed air leak is detected and Icing conditions........................... Avoid P FLT CTRL
the Nacelle 3 and 4 shutoff
valves and right wing isolation Right wing ice protection zone is
valve are closed. inoperative. R GEAR
If ice accumulation is suspected:
Landing with Ice Accumulation S DOR/RMP
PERF R WING HEAVY procedure........................... Accomplish
A difference of greater than Fuel balance............................ Restore T JETTISON
1,500 pounds in total fuel
between the right and left wings Use Transfer, CROSS FEED and U
(excluding auxiliary tanks). CROSS SHIP switches to bring LANDING
within limits.
If the ACAWS occurs during fuel V
dumping: DITCHING
Start and stop the transfer pump(s) W
in the fuel tanks on the left wing as
needed to bring within limits. BAILOUT
X
OPER FAULT LG
174 Use, copying and/or disclosure is
-
governed by the statement on the
BACK title page of this document. CHARTS