Page 90 - (KU)01-75GAJ-1.5 - Change 1
P. 90

INTRO


   EP'S                  (KU)01-75GAJ-1.5                                                             A     FIGURES


                                              1.2.2 CAUTIONS                                          B
                                                                                                             ACAWS
                                Alert/Condition                     Crew Action
                          R EXT FWD XFR PMP FAIL                                                      C     GROUND
                          The pressure switch senses     CROSS FEED switches (all)...... CLSD
                          less than 23 psig, the R EXT                                                D
                          transfer FROM switch is on,    CROSS SHIP switch................... Open
                          there is more than 400 pounds   Transfer FROM switches (all except R              TAKEOFF
                          of fuel indicated in the tank,   EXT).............................................. OFF  E
                          and fuel is not being defueled,
                          transferred (to tanks or AR pod)   Transfer TO switches................. CLSD  F  FIRE/SMK
  NORM                    or dumped.                     Pump pressure............................ Verify

                                      OR                 If pump pressure is less than 23 psi:              PRES/OXY
                          The R EXT transfer FROM        R EXT transfer FROM switch....... OFF       G
                          switch is on, there is more than
                          400 pounds of fuel indicated in   R EXT TK AFT PMP ECB (738).... PULL       H    ENG/PROP
                          the tank, fuel is being defueled,   Do not turn the pump on or reset
                          transferred (to tank or AR        the ECB until proper inspection
                          pod) or dumped, and the FMC       and repairs have been performed.          I
                          detects low pump electrical    R EXT transfer FROM switch.......... On               FUEL
                          current.
                                                            This will use the other right             L
                                                            external tank pump.                                AAR
                                                            If both pumps in the tank fail,
                                                            the fuel in the tank is unusable.        M
  SPEC                              NOT FOR FLIGHT                                                             ELEC
                                                            Recalculate the total usable fuel.
                                                         If the ACAWS clears or pump pressure         N
                                                         is greater than or equal to 23 psi:
                                                         Continue pump operation.                              HYD
                          R EXT TK HEAVY                                                             O
                          Fuel quantity difference of    Fuel balance............................ Restore   FLT CTRL
                          more than 1,000 pounds exists     Use Transfer, CROSS FEED and              P
                          between external tanks.           CROSS SHIP switches, as required.
                          R HOR TAIL HEAT FAIL                                                        R       GEAR
                          The BA/ECS has detected        Icing conditions............................. Avoid
                          that the right horizontal tail ice   If failure is due to insuf¿cient bleed air
                          protection zone may not be     supply:                                      S     DOR/RMP
  PERF                    KHDWLQJ VXI¿FLHQWO\ WR UHPRYH   HP...................................... As required
                          ice. The ice protection zone
                          valve may be failed closed or     Advance at least two engines to           T     JETTISON
                          EOHHG DLU PD\ EH LQVXI¿FLHQW      minimum HP shown on the power
                                                            setting schedule in Chapter 12            U
                                                            (1,300 HP above 20,000 feet,                    LANDING
                                                            incrementally reducing the power
                                                            by 100 HP every 5,000 feet until          V
                                                            reaching 5,000 feet where 750 HP
                                                            should be maintained).                          DITCHING
                                                         Verify the ACAWS clears following the       W
                                                         next cycle (approximately 6 minutes).
                                                         If ice accumulation is suspected:            X     BAILOUT
                                                         Landing with Ice Accumulation
  OPER                                                   procedure........................... Accomplish    FAULT LG

                                                          -
                                                         172               Use, copying and/or disclosure is
                                                                           governed by the statement on the
                                                         BACK              title page of this document.      CHARTS
   85   86   87   88   89   90   91   92   93   94   95