TotalAlert Infinity™ NFPA Medical Gas Notification System
1.6 TotalAlert Infinity™ Medical Gas Notification System Parent Model
Number Chart
T3 - ___ - _ Variable C
Gas Type (Area and Combination Only)
B C
Allowable Value Description
Variable B O Oxygen
Alarm Type and Size
X Nitrous Oxide
Allowable Value Description
A Medical Air
A10 Area Alarm, Up to 8 Area Gases
V Medical Vacuum
M01 Master, 0 Inputs, 16 Relay Outputs
W WAGD
M10 Master, 20 Inputs
N Nitrogen
M11 Master, 20 Inputs, 16 Relay Outputs
C Carbon Dioxide (CO2)
M12 Master, 20 Inputs, 32 Relay Outputs
D Oxygen 100 psig
M13 Master, 20 Inputs, 48 Relay Outputs
F Medical Air 100 psig
M20 Master, 40 Inputs
G Carbon Dioxide 100 psig
M21 Master, 40 Inputs, 16 Relay Outputs
9 Instrument Air
M22 Master, 40 Inputs, 32 Relay Outputs
1 CO2-O2 (CO2 over 7%)
M30 Master, 60 Inputs, 0 Relay Outputs
2 O2-CO2 (CO2 not over 7%)
M31 Master, 60 Inputs, 16 Relay Outputs
3 HE-O2 (HE over 80%)
C01 Combination, 10 Inputs, 6 Relay Out-
puts, Up to 3 Area Gases 4 O2-HE (HE not over 80%)
C10 Combination, 20 Inputs, Display up to 7 Laboratory Air
6 Area Gases 8 Laboratory Vacuum
C11 Combination, 20 Inputs, 16 Relay Out- H Helium
puts, Display up to 6 Area Gases J Argon
C12 Combination, 20 Inputs, 32 Relay Out- S Surgical Air
puts, Display up to 6 Area Gases
B AGSS
C20 Combination, 40 Inputs, Display up to
6 Area Gases E N2O-O2
C21 Combination, 40 Inputs, 16 Relay Out- M Mixed Gas
puts, Display up to 6 Area Gases Example: TotalAlert Infinity™ Master Alarm with 40 Inputs
C30 Combination, 60 Inputs, Display up to and 32 Relay Outputs
6 Area Gases Example Model Number: T3-M22
C40 Combination, 7 Inputs, 6 Relay Out- Example: TotalAlert Infinity™ AREA Alarm with 4 gases - Oxy-
puts, 4 Inputs for 4-20mA devices gen, Nitrous Oxide, Medical Air, and Vacuum
C41 Combination, 27 Inputs, 6 Relay Out- Example Model Number: T3-A10-OXAV
puts, 4 Inputs for 4-20mA devices
C42 Combination, 47 Inputs, 6 Relay Out- Example: Combination Alarm with 10 Inputs, 6 Relay
puts, 4 Inputs for 4-20mA devices Outputs, and 3 gases - Oxygen, Medical Air, and Medical
Vacuum
C43 Combination, 67 Inputs, 6 Relay Out- Example Model Number: T3-C01-OAV
puts, 4 Inputs for 4-20mA devices
C44 Combination, 7 Inputs, 6 Relay Out- Example: Combination Alarm with 7 Inputs, 6 Relay Out-
puts, 4 Inputs for 4-20mA devices, Up puts, 4 4-20mA devices, and 2 gases - Oxygen, Medical Air
to 6 Area Gases (maximum display of 6 Example Model Number: T3-C44-OA
gas badges, in combination of 4-20mA
and gas sensors) NOTE:
NOTE: For Area Alarm panels, sensor assemblies are not Standard configurations listed above. For
specific to "Remote" or "Local" installations. It is not special configurations contact BeaconMed-
necessary to designate the installation type in the model
numbering. aes Customer Service (888) 463-3427.
4107 9016 58.02 1-10