Page 111 - Feed Lab
P. 111
Estimation of Wax in Oil and Fat Suguna Management System Ver 1.0 / SOP / FQL / P2 - 25 Page 2 of 2
Picture - 6 Picture - 7 Picture - 8 Picture - 9
CALCULATION
W1 - W2
Wax % = ----------------------------------- X 100
Sample weight, g
Where,
W1 = Initial weight of centrifuge,
W2 = Final weight of centrifuge tube (with wax).
Prepared by : Approved by :
99 Director - Technical