Page 110 - Feed Lab
P. 110
Suguna Management System Ver 1.0 / SOP / FQL / P2 - 25 Page 1 of 2
25. Estimation of Wax in Oil
SCOPE
To estimate the Wax in oil / Fat.
APPARATUS
FAnalytical Balance, 1 mg / 0.1 mg accuracy
(Picture -1)
FCentrifuge tube (Picture - 2)
FHot Air Oven pre calibrated (Picture - 3)
Picture - 5
FCentrifuge (Picture - 4)
FNi - Spatula (Picture - 5) CHEMICALS
Chilled Acetone :
Cool the Acetone in the refrigerator.
PROCEDURE
FTake 10 gm of oil in a centrifuge tube and centrifuge
the oil for 30 minutes at 2000rpm. (Picture - 6)
FAdd equal quantity of Chilled acetone to centrifuge
tube. Shake well for 5 minutes, again centrifuge for
Picture - 1 Picture - 2
15 minutes at 2000 rpm. (Picture - 7)
FTake the tube out, discard the top layer only. Add
10 ml of chilled acetone and repeat the above
steps for 4 times. (Picture - 8)
FAfter 4th time of removal of top layer, keep the
centrifuge tube in oven for 20 minutes, cool and
weigh. (Picture - 9)
Picture - 3 Picture - 4
Prepared by : Approved by :
98 Director - Technical