           28. Estimation of Colour of Oil


                                                                   sample, initially by using the color racks in the ratio
           SCOPE
                                                                   of 10 yellow to 1 red. Correct until an accurate color
           Applicable to testing of all vegetable fats and oils.
                                                                   match  is  obtained  without  unnecessarily  main-
                                                                   tainting the  ratio  of  10  yellow to 1 red  & using the
           OBJECTIVE
                                                                   minimum number of blue or Neutral units to obtain
           The method determines color by matching the color of    the  match  but  not  more  than  9.0  blue  and  3.0
           the light transmitted through  a specified depth of liquid   neutral.
           or oil to the color of the light originating from the same
           sour the transmitted through glass color standards   FThe chemist may rest the eyes after each 30-sec
                                                                   period of matching.
           APPARATUS
                                                                FRecord the size of cell used and the red yellow, blue
           FLovibond Universal Tintometer                          or neutral readings forming the color match.

           FGlass Cells : Made of optical glass with optical    FAcceptance color reading difference:
              path length as following:
              1. 6.4 mm (1/4")                                          Reading           Acceptable Differences

              2. 25.4 mm (1")                                     Up to 0.9 red               0.2 Red
                                                                  From 1.0 red to 2.9 red     0.4 Red
              3. 133.4 mm (5¼" Cell)
                                                                  From 3.0 red to 4.0 red     0.5 Red
           PROCEDURE
                                                                  From 4.1 red to 12 red      1.0 Red
           FIt is essential that the determination is carried out in
              subdued ambient light i.e. not facing a window or
              direct sunlight.

           FPour the prepared sample into a clean & dry cell of   CALCULATION
              required  length  to  give  color  readings  within  the   The number of red, yellow and blue or neutral readings
              range given in Apparatus.                         needed to obtain the match and the formula used Y+

           FPlace  the  cell  containing  the  sample  in  the   5R for the length of cell used ¼", 1" or 5¼" For crude oil
              Tintometer. Immediately determine the color of the   bleached oil and refined oil respectively.