Suguna Management System      Ver 1.0 / SOP / FQL / P2 - 08 Page  1 of 2



























           8. Estimation of Sand & Silica



           SCOPE
            To estimate the sand and silica (Acid Insoluble Ash) in
           feed and feed stuffs.


           PRINCIPLE
           The  total  ash  is  dissolved  in  dilute  acids  when  all
           minerals except sand and silica go into solution. The
           solution  is  filtered  off  and  the  residue  left  behind  is
                                                                        Picture-1                Picture-2
           ignited, cooled and weighed to get the acid insoluble
           ash.


           Apparatus
           FAnalytical  Balance,  1  mg  /  0.1  mg  accuracy
              (Picture-1)

           FHot Air Oven (Picture-2)

           FMuffle furnace (Picture-3)
           FFilter paper - What man No.1/615A (Picture-4)               Picture-3                Picture-4

           FNi-Spatula (Picture-5)

           FPlastic funnel, 70 mm diameter (Picture-6)

           FPlastic conical flask, 250 ml (Picture-7)
           FSilica crucible, 25 ml (Picture-8)





                                                                        Picture-5                Picture-6





          Prepared by :                                                             Approved by :