Page 75 - Feed Lab
P. 75
Suguna Management System Ver 1.0 / SOP / FQL / P2 - 08 Page 1 of 2
8. Estimation of Sand & Silica
SCOPE
To estimate the sand and silica (Acid Insoluble Ash) in
feed and feed stuffs.
PRINCIPLE
The total ash is dissolved in dilute acids when all
minerals except sand and silica go into solution. The
solution is filtered off and the residue left behind is
Picture-1 Picture-2
ignited, cooled and weighed to get the acid insoluble
ash.
Apparatus
FAnalytical Balance, 1 mg / 0.1 mg accuracy
(Picture-1)
FHot Air Oven (Picture-2)
FMuffle furnace (Picture-3)
FFilter paper - What man No.1/615A (Picture-4) Picture-3 Picture-4
FNi-Spatula (Picture-5)
FPlastic funnel, 70 mm diameter (Picture-6)
FPlastic conical flask, 250 ml (Picture-7)
FSilica crucible, 25 ml (Picture-8)
Picture-5 Picture-6
Prepared by : Approved by :
63 Director - Technical