           7. Estimation of Total Ash



           SCOPE
           To estimate the Total ash in feed and feed stuffs.

           PRINCIPLE
           The  total  content  of  mineral  matter  i.e.  Non-
           combustible portion of the feed is called total ash.


           APPARATUS
                                                                        Picture-3                Picture-4
           FAnalytical  Balance,  1  mg  /  0.1  mg  accuracy
              (Picture-2)
                                                                PROCEDURE
           FMuffle furnace (Picture - 1)                        FTake silica crucible record empty weight (A) and

           FSilica crucible, 25 ml (Picture - 3)                   tare it. (Picture - 5)

           FDesiccators. (Picture - 4)                          FThen weigh 2 gm of sample in a silica crucible.
                                                                   Ignite the sample on a burner till smoke cease off.
                                                                   (Picture - 6)

                                                                FPlace the crucible in a muffle furnace and heat to
                                                                       o
                                                                                 o
                                                                   600 C  +/-  20   C.  Kept  for  90  minutes.  At  this
                                                                   temperature all organic matter will be burnt leaving
                                                                   behind  minerals.  Remove  the  crucible  from  the
                                                                   furnace carefully and cool it in desiccators to room
                                                                   temperature and weigh again (B).(Picture - 7)

                                                                Note:
                                                                1. The  ash  may  be  used  for  the  determination  of
                   Picture-1               Picture-2
                                                                   minerals and acid insoluble ash.
                                                                2.  Since the ash is hygroscope, weighing should be
                                                                   done quickly after taken out from dessicator.