2.5  Level 1 Theory (3/3) – Minimum Output and Criteria
            2.5.1  Minimum report output for Level 1
            The main results to evaluate and report for a Level 1 analysis are:

                                      Weld   Line   (Angle   and
                   Melt Front Time                          Air Trap                     Commented [AB13]: Put back in table (Anthony)
                                      Temperature)
                   Gate Contribution   Cavity Temperature   Shear Stress

                   Cavity Pressure    Sprue Pressure Curve   Flow Rate Curve

            2.5.2  Checking criteria
            For every analysis, there are a series of questions to ask, which will help to ensure that the results are
            looked at completely:
            2.5.2.1  Will the part fill completely?
            It is important to ensure that the part fills out completely.  If the part does not fill out, then there is no
            reason to look at the remainder of the results, as a partially filled cavity, or short shot, will skew the results
            for the remainder of the analysis interpretation.
            For this question, look at:
               •  Melt Front Time – Look to see if the cavity is fully filled.  A partially filled part will have a discolored
                 section.