Page 45 - Moldex3d training Manual
P. 45

stages.  Increasing this number will effectively reduce the number of iterations, making the simulation
            faster.
            To adjust this value, go to the “Advanced” button, and then to the “Accuracy/Performance” tab.  The
            “Flow Solver” is the parameter for Solver Acceleration.






















            When  adjusting  this  value,  it  is  important  to  note  that  if  there  are  too  few  iterations  made  (Solver
            Acceleration is too high), then the simulation can become unstable and ultimately diverge, resulting a
            failed simulation with no results to look at.

            It is recommended to keep this value between one (1) and five (5).  The default setting for computation
            using a BLM-type mesh is three (3).
            2.4.5.3  Computation Sequence
            For a simple Flow analysis, the Analysis sequence will be Filling – F, which will launch only the filling
            analysis.  For faster simulation results, the Quick Flow – Fq can be used.  This type of analysis will run very
            quickly but will provide limited  analysis results.   This  should only be used for  flow balance and gate
            placement.

















                                               44