Page 220 - FreesStyler® Installation and Startup
P. 220

®
            INSTALLATION AND STARTUP


            Chapter 10 Initial Startup



            Startup Procedure
                                                  CAUTION


                     Motors should not be run unloaded or uncoupled from the pump at any
                                  time; damage to the motor bearings will occur.
               REMINDER: Do not start the pump before priming or venting the pump (Figure 5d). Never operate the pump dry.

               Freeze Protection
               If the pump is installed in an area where freezing could occur, the pump and system should be drained during freezing temperatures
               to avoid
               damage. To drain the pump, close the isolation valves, remove the priming plug and drain plug at the base of the pump. Do not
               replace the plugs until the pump is to be used again. Always replace the drain plug with the original or exact replacement. Do not
               replace with a standard plug. Internal recirculation will occur, reducing the output pressure and flow.

               Chemical Tire Applicator (if applicable)
                   a)  The first thing to do is contact your chemical supplier they will know the correct dilution ratio for the specific chemical you
                       will be using as well as the climate of your location. Dilution is adjusted by changing the induction tip located on the
                       hydrominder assembly.
                   b)  Insert the chemical pick up tube into the raw chemical container.
                   c)   Make sure that the foam air regulator is turned all the way down by rotating the adjustment knob clockwise.
                   d)  Force the CTA output function in your controller on energizing the CTA timer panel.
                   e)  While pressing the prime button located on the timer enclosure adjust pump air pressure to 60PSI, continue holding the
                       prime button once the lines are full. Adjust the foam air regulator to 20PSI, release the prime button and return the CTA
                       function in your control panel back to the auto position.
                   f)   Run some cars and adjust the nozzles on the applicators to maximize coverage on both wide and narrow vehicles.